Unit W1 |
Config Type A |
Scale Rad 1:1 · Ax 1:2 |
Nine coolers, one per packaging machine, in two configuration types. The type sets the number of tube-couples (paths), and so the number of measurement locations per unit.
| Configuration | Units | Qty | Measurement locations |
|---|---|---|---|
| Type A — Single tube-couple (one-path) | W1, W2, W7 | 3 | L1, L2 |
| Type B — Dual tube-couple (two-path) | W3, W4, W5, W6, W8, Doypak1 | 6 | L1, L2, L3, L4 |
Total inspected: 9 coolers — 3 one-path units + 6 two-path units.
| Parameter | Value |
|---|---|
| Equipment type | Tubular heat exchanger / cooler |
| Model / tag nos. | W (WinPack) 1–8 & Doypak 1 |
| Internal tube material | AISI 316L |
| Shell / outer tube material | AISI 304L |
| Nominal internal tube thickness | 2.0 mm |
| Design pressure | 9 bar & 15 bar (per unit type) |
| Service | Product cooling — sachet / Doypack packaging lines |
L and T are both numbered 1–4 and mean different things. L counts internal pipes along the unit · T counts concentric tubes across the section.